Anti-scatter grid

From WikiMD's Food, Medicine & Wellness Encyclopedia

Anti-scatter grid is a device used in radiography to improve the quality of images produced by reducing the amount of scatter radiation that reaches the X-ray film or digital detectors. Scatter radiation is a form of secondary radiation that occurs when the primary x-rays interact with the subject being imaged, such as a patient's body in medical imaging. This scattered radiation can degrade the quality of the image by creating unwanted noise and reducing contrast, making it harder to interpret the results accurately.

Function and Design[edit | edit source]

The primary function of an anti-scatter grid is to absorb scattered radiation before it reaches the imaging detector while allowing the primary radiation to pass through. This is achieved through a series of thin, parallel strips of radiopaque material, typically made of lead, separated by radiolucent (radiation-passing) material. The grid is placed between the patient and the imaging detector. The design of an anti-scatter grid is characterized by two main parameters: the grid ratio and the line density. The grid ratio is the ratio of the height of the radiopaque strips to the distance between them, and the line density refers to the number of lines per unit length. Higher grid ratios and line densities are more effective at scatter reduction but also absorb more primary radiation, which can necessitate increased exposure times.

Types of Anti-scatter Grids[edit | edit source]

There are several types of anti-scatter grids, each designed for specific applications or imaging modalities. The most common types include:

  • Linear grids: These grids have strips aligned in a single direction. They are the most widely used type and are particularly effective for general radiography.
  • Crossed grids: Consist of two linear grids superimposed at right angles to each other. They are more effective at scatter reduction than linear grids but can cause more primary radiation absorption.
  • Focused grids: These grids have strips that are angled, or focused, to match the divergence of the x-ray beam. This design minimizes the absorption of primary radiation and is especially useful in radiography of body parts with varying thickness.
  • Moving grids: Also known as reciprocating grids, these are mechanically moved during the exposure to blur the grid lines, preventing them from appearing on the final image. They are commonly used in fluoroscopy.

Applications[edit | edit source]

Anti-scatter grids are used in various radiographic imaging modalities, including CT scans, Mammography, and conventional X-ray imaging. Their use is particularly important in imaging body parts with significant differences in thickness or density, where scatter radiation can significantly degrade image quality. However, their use is not without drawbacks. The absorption of primary radiation by the grid can increase the radiation dose to the patient, and the physical presence of the grid can introduce artifacts if not properly aligned or if it is of poor quality.

Conclusion[edit | edit source]

Anti-scatter grids play a crucial role in radiographic imaging by improving image quality through the reduction of scatter radiation. Their design and application require careful consideration of the balance between image quality and patient radiation dose. As imaging technology advances, the development of new grid types and materials continues to evolve, aiming to further enhance the diagnostic capabilities of radiographic imaging.


Wiki.png

Navigation: Wellness - Encyclopedia - Health topics - Disease Index‏‎ - Drugs - World Directory - Gray's Anatomy - Keto diet - Recipes

Search WikiMD


Ad.Tired of being Overweight? Try W8MD's physician weight loss program.
Semaglutide (Ozempic / Wegovy and Tirzepatide (Mounjaro) available.
Advertise on WikiMD

WikiMD is not a substitute for professional medical advice. See full disclaimer.

Credits:Most images are courtesy of Wikimedia commons, and templates Wikipedia, licensed under CC BY SA or similar.


Contributors: Prab R. Tumpati, MD